Circuit Breaker Replacement Parts
Westinghouse 50DHP250 Renewal Parts
Click on part number for quote
Description | Part Number |
---|---|
1200A | |
15 KV Motor for 125 V DC / 115 V AC breaker built after 1970 | N/A |
15 KV Motor for 250 V DC / 230 V AC breaker built after 1970 | N/A |
15 KV Motor for 48 V DC breaker built after 1970 | N/A |
5 KV Motor for 125 V DC / 115 V AC breaker built after 1970 | 422D127G01 |
5 KV Motor for 250 V DC / 230 V AC breaker built after 1970 | 422D127G02 |
5 KV Motor for 48 V DC breaker built after 1970 | 422D127G03 |
Arc Chute Complete | 437D48G01 |
Arc Chute Hinge / Contact Assembly | 592C698G02 |
Arc Chute Support | N/A |
Arc Shield Front Left-Rear Right | N/A |
Arc Shield Front Right-Rear Left | N/A |
Arc Shield Spacer | N/A |
Arc Shield-Bottom | N/A |
Arc Shield-L.H. | 423D170H02 |
Arc Shield-R.H. | 423D170H01 |
Arcing Horn Replacement Kit | 792A134G01 |
Auxiliary Switch (Lower) | 46A9047G05 |
Auxiliary Switch (Upper) | 46A9047G04 |
Auxiliary Switch Operating Link | 437D248G01 |
Barrier Complete | 6435C22G01 |
Barrier Front Panel | 693C353G01 |
Barrier Mounting Clips | 3712A44H01 |
Barrier Mounting Pan | 437B626G02 |
Barrier Nylon Screw Kit | 8242A64G01 |
Bearing Plate (Levering Device) | 501B752H01 |
Blow Out Coil | 310C716G01 |
Bottle Assemblies | 792A132G01 |
Bottle Barrier | 502A540H01 |
Breaker Position Indicator and MOC Switch Operating Pin | 791A620G01 |
Breaker Position Interlock | 792A146G01 |
Bumper Pad Kits (3 pads and 6 pins) | 792A144G01 |
Close & Trip Linkage | 503B365G01 |
Close Coil for 15 KV / 125 V DC (40 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 125 V DC (60 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 250 V DC (40 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 250 V DC (60 KA momentary current rating breakers) | N/A |
Close Coil for 5 KV / 250 V DC | 676625 |
Close Coil for 5 KV / 125 V DC | 676631 |
Closing Latch & Trigger Assembly Kit (Link Type) | 792A116G01 |
Closing Latch & Trigger Assembly Kit (Plunger Type) | 792A116G02 |
Closing Latch & Trigger Kit | 792A244G01 |
Closing Spring | 503B411H01 |
Closing Springs VKit | 792A248G01 |
Complete Contact Assembly (Stationary Main and Arcing-Moving Main and Arcing) | 6426C73G02 |
Connecting Link (between two auxiliary switches) | 383GA53H01 |
Control Relay "X" 15 KV / 125 V DC | N/A |
Control Relay "X" 5 KV / 125 V DC | 423D181G02 |
Control Relay "X" 5 KV / 250 VV DC | 423D181G03 |
Control Relay "X" for 15 KV / 250 V DC | N/A |
Control Relay "Y" 115 V AC 60 HZ | 8263A53G01 |
Control Relay "Y" 125 V DC | 8257A30H04 |
Control Relay "Y" 230 V AC 60 HZ | 8263A53G02 |
Control Relay "Y" 250 V DC | 8257A30H05 |
Control Relay "Y" 48 V DC | 8257A30H03 |
Crank Assembly | 691C009G01 |
Cutoff Switch Cam, End Washer & Retainer Bolt | 792A119G01 |
Driving & Holding Pawl Kit | 6426C87G01 |
Driving Pawl Kit | 792A246G01 |
End Plate | N/A |
Fastener Kit (DHP) | 8184A69G01 |
Glass Rope Insulation | 41514CG41D |
Ground Contact Cluster | 310C665G01 |
Holding Pawl Kit | 437B497G02 |
Interlock Kit | 8257A77G01 |
Kit- 2 Lower Pole Unit Insulators | 792A097G01 |
Kit- 2 Upper Pole Unit Insulators | 792A097G01 |
Kit-Misc. Cover for Switches, Relay, Located on Mech. Panel | 792A088G01 |
Latch Check Switch | 662A143H01 |
Latch Checking Switch | 784A907H01# |
Levering-in Assembly Replacement Lit | 8068A62G01 |
Levering-in Screw | 423D184G01 |
Main & Transfer Stack Assembly Kit | 6426C84G02 |
Mech. Assembly W/ Close Spring W/O Spring Charge Motor | 6426C81G01 |
Mech. Small Springs-Kit | 6426C70G01 |
Mechanism-Operated Cell Switch-Installation Kit One (1) Switch (Operates in Connected Position Only) | 693C612G04 |
Mechanism-Operated Cell Switch-Installation Kit One (1) Switch (Operates in Connected/Test Position) | 693C612G01 |
Mechanism-Operated Cell Switch-Installation Kit Three (3) Switch (Operates in Connected Position Only) | 693C612G06 |
Mechanism-Operated Cell Switch-Installation Kit Three (3) Switch (Operates in Connected/Test Position) | 693C612G03 |
Mechanism-Operated Cell Switch-Installation Kit Two (2) Switch (Operates in Connected/Test Position) | 693C612G02 |
Mechanism-Operated Cell Switch-Installation Kit Two(2) Switch (Operates in Connected Position Only) | 693C612G05 |
Mechanism-Operated Cell Switch-Replacement Kit One (1) Switch | 792A147G01 |
Mechanism-Operated Cell Switch-Replacement Kit Two (2) Switches | 792A147G02 |
Misc. Springs Kit | 691C0111G01 |
Misc. Springs Package-Kit | 6426C72G01 |
Motor Cutoff Switch (2 Circuit) 4 Terminals | 8257A30H01 |
Motor Cutoff Switch (4 Circuit) 8 Terminals | 8257A30H02 |
Motor Cutoff Switch and Indicator (Less Switches) | 591C993G07 |
Motors for 125 V DC / 115 V AC breaker built after 1970 | 3755A95G01 |
Motors for 250 V DC / 230 V AC breaker built after 1970 | 3755A95G02 |
Motors for 48 V DC breaker built after 1970 | 3755A95G03 |
Moving Arcing Contact | 691C404G01 |
Moving Contact Operating Rod | 501B713G01 |
Opening (Accelerating) Springs-Kit | 6426C71G01 |
Opening Springs Kit-Cast Solenoid | 691C014G03 |
Opening Springs Kit-Cast Stored Energy | 691C014G01 |
Operating Rod Assembly | 3838A54G01 |
Operations Counter | 592C040H01 |
Pole Unit (For Field Replacement) (Monolithic to PIP) (58KA) | 568F447G02 |
Pole Unit (For Field Replacement) (Monolithic to PIP) (78KA) | 568F447G04 |
Porcelain Hinge Support Assembly | 592C682G01 |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-1200 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-1200 Amp Upper (Short) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-2000 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-2000 Amp Upper (Short) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-1200 Amp Lower (Long) | 437D911G02 |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-1200 Amp Upper (Short) | 437D911G01 |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-2000 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-2000 Amp Upper (Short) | N/A |
Primary Disconnecting Contact | 502A851G01 |
Puffer Tube Assembly | 507B993G01 |
Pull Fuse Holder Assembly w/o Fuses-2 Pole, 30 Amp | 347A062H03 |
Pull Fuse Holder Assembly w/o Fuses-2 Pole, 60 Amp | 783A603H01 |
Rail Latch Assembly | 792A083G01 |
Ratchet & Cam Assembly Less Crank Assembly | 792A120G01 |
Rear Arc Horn Contact | N/A |
Resistor Assembly 115 V AC 60 HZ 250 Ohm | 502A006H13 |
Resistor Assembly 125 V DC 200 Ohm | 73432ECOHE |
Resistor Assembly 230 V AC 60 HZ 750 Ohm | 502A006H15 |
Resistor Assembly 250 V DC 750 Ohm | 73432ECOMB |
Resistor Assembly 48 V DC 25 Ohm | 73432ECOBD |
Resistor for 15 KV / 7500 Ohm | N/A |
Resistor for 15KV / 2000 Ohm | N/A |
Resistor for 5 KV / 2000 Ohm | 74342ECOQO |
Resistor for V5 KV /7500 Ohm | 73432ECOUQ |
Secondary Contact ( Includes Block and Guide Pins | 792A086G01 |
Secondary Contact Handle Assembly | 792A087G01 |
Secondary Contact Receptacle | 4A7850A05 |
Secondary Contact Support | 437D249G01 |
Shunt Strap | 6898D75H01 |
Shunt Trip Magnet (Plus Coil) | 592C921G01 |
Shutter Assembly Complete | 437D937G01 |
Shutter Only | 437D937G02 |
Shutter Roller Kit | 792A084G01 |
Side Sheet-L.H. | 548F260G01 |
Side Sheet-R.H. | 548F259G01 |
Single Pole Unit Assembly Complete (less finger clusters and lift rod) | 568F566G02 |
Small Springs Kit | 691C012G01 |
Small Springs Kit | 691C013G01 |
Space Heater 100W @ 250V | 3614A50H05 |
Space Heater 250W @ 125 V | 3614A50H01 |
Space Heater 250W @ 250 V | 3614A50H02 |
Space Heater 375W @ 125 V | 3614A50H03 |
Space Heater 375W @ 250 V | 3614A50H04 |
Space Heater 95W @ 125 V | 3614A50H04 |
Spring Release Coil 115 V AC 60 HZ | 677C903G05 |
Spring Release Coil 125 V DC | 677C903G02 |
Spring Release Coil 230 V AC 60 HZ | 677C903G06 |
Spring Release Coil 230 V DC | 677C903G03 |
Spring Release Coil 48 V DC | 677C903G01 |
Spring Release Magnet (Plus Coil) | 592C921G01 |
Stationary Arcing Contact | 501B812G01 |
Stud Assemblies-Bottom Stud (4th Position CT) | 792A123G04 |
Stud Assemblies-Bottom Stud (Bus Tie Unit) | 792A123G03 |
Stud Assemblies-Bottom Stud (Feeder) | 792A123G02 |
Stud Assemblies-Top Stud (Bus) | 792A123G01 |
Terminal Block w/ Marking Strip-12 Point | 8261A60G03 |
Terminal Block w/ Marking Strip-8 Point | 8261A60G02 |
Trip Cam Adj. Screw & Nut | 792A118G01 |
Trip Coil 115 V AC 60 HZ for Capacitor Trip Device 382D719G06 | 677C903G03 |
Trip Coil 115 V AC 60 HZ for Capacitor Trip Device 689C166G02 | 677C903G07 |
Trip Coil 125 V DC | 677C903G02 |
Trip Coil 24 V DC | 677C903G04 |
Trip Coil 250 C DC | 677C903G03 |
Trip Coil 48 V DC | 677C903G01 |
Trip Latch & Trigger Kit | 792A245G01 |
Trip Latch & Trigger Kit | 792A247G01 |
Tripping Latch & Trigger Assembly Kit (Link Type) | 792A117G01 |
Tripping Latch & Trigger Assembly Kit (Plunger Type) | 792A117G02 |
Truck-Operated Cell Switch- Three (3) Switch Installation Kit | 792A092G03 |
Truck-Operated Cell Switch- Two (2) Switch Installation Kit | 792A092G02 |
Truck-Operated Cell Switch-One (1) Switch Installation Kit | 792A092G01 |
Truck-Operated Cell Switch-Replacement Kit -One (1) Switch | 792A091G01 |
Tube & Nut Assembly | 8252A34G01 |
Undervoltage Coils 125 VDC | 6911D45G05 |
Undervoltage Coils 250 VDC | 6911D45G01 |
Undervoltage Coils 48 VDC | 6911D45G09 |
Undervoltage Coils Capacitor Time Delay | 677C904G01 |
Undervoltage Trip Device | 693C611G01 |
Wheels-Including Pins and Rings (3 Inch) Set of 4. | 792A085G01 |
Wheels-Including Pins and Rings (4 Inch) Set of 4. | 792A085G02 |
2000A | |
15 KV Motor for 125 V DC / 115 V AC breaker built after 1970 | N/A |
15 KV Motor for 250 V DC / 230 V AC breaker built after 1970 | N/A |
15 KV Motor for 48 V DC breaker built after 1970 | N/A |
5 KV Motor for 125 V DC / 115 V AC breaker built after 1970 | 422D127G01 |
5 KV Motor for 250 V DC / 230 V AC breaker built after 1970 | 422D127G02 |
5 KV Motor for 48 V DC breaker built after 1970 | 422D127G03 |
Arc Chute Complete | 437D48G01 |
Arc Chute Hinge / Contact Assembly | 592C698G02 |
Arc Chute Support | N/A |
Arc Shield Front Left-Rear Right | N/A |
Arc Shield Front Right-Rear Left | N/A |
Arc Shield Spacer | N/A |
Arc Shield-Bottom | N/A |
Arc Shield-L.H. | 423D170H02 |
Arc Shield-R.H. | 423D170H01 |
Arcing Horn Replacement Kit | 792A134G01 |
Auxiliary Switch (Lower) | 46A9047G05 |
Auxiliary Switch (Upper) | 46A9047G04 |
Auxiliary Switch Operating Link | 437D248G01 |
Barrier Complete | 6435C22G01 |
Barrier Front Panel | 693C353G01 |
Barrier Mounting Clips | 3712A44H01 |
Barrier Mounting Pan | 437B626G02 |
Barrier Nylon Screw Kit | 8242A64G01 |
Bearing Plate (Levering Device) | 501B752H01 |
Blow Out Coil | 310C716G01 |
Bottle Assemblies | 792A133G01 |
Bottle Barrier | 502A540H01 |
Breaker Position Indicator and MOC Switch Operating Pin | 791A620G01 |
Breaker Position Interlock | 792A146G01 |
Bumper Pad Kits (3 pads and 6 pins) | 792A144G01 |
Close & Trip Linkage | 503B365G01 |
Close Coil for 15 KV / 125 V DC (40 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 125 V DC (60 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 250 V DC (40 KA momentary current rating breakers) | N/A |
Close Coil for 15 KV / 250 V DC (60 KA momentary current rating breakers) | N/A |
Close Coil for 5 KV / 250 V DC | 676625 |
Close Coil for 5 KV / 125 V DC | 676631 |
Closing Latch & Trigger Assembly Kit (Link Type) | 792A116G01 |
Closing Latch & Trigger Assembly Kit (Plunger Type) | 792A116G02 |
Closing Latch & Trigger Kit | 792A244G01 |
Closing Spring | 503B411H01 |
Closing Springs VKit | 792A248G01 |
Complete Contact Assembly (Stationary Main and Arcing-Moving Main and Arcing) | 6426C73G04 |
Connecting Link (between two auxiliary switches) | 383GA53H01 |
Control Relay "X" 15 KV / 125 V DC | N/A |
Control Relay "X" 5 KV / 125 V DC | 423D181G02 |
Control Relay "X" 5 KV / 250 VV DC | 423D181G03 |
Control Relay "X" for 15 KV / 250 V DC | N/A |
Control Relay "Y" 115 V AC 60 HZ | 8263A53G01 |
Control Relay "Y" 125 V DC | 8257A30H04 |
Control Relay "Y" 230 V AC 60 HZ | 8263A53G02 |
Control Relay "Y" 250 V DC | 8257A30H05 |
Control Relay "Y" 48 V DC | 8257A30H03 |
Crank Assembly | 691C009G01 |
Cutoff Switch Cam, End Washer & Retainer Bolt | 792A119G01 |
Driving & Holding Pawl Kit | 6426C87G01 |
Driving Pawl Kit | 792A246G01 |
End Plate | N/A |
Fastener Kit (DHP) | 8184A69G01 |
Glass Rope Insulation | 41514CG41D |
Ground Contact Cluster | 310C665G01 |
Holding Pawl Kit | 437B497G02 |
Interlock Kit | 8257A77G01 |
Kit- 2 Lower Pole Unit Insulators | 792A097G01 |
Kit- 2 Upper Pole Unit Insulators | 792A097G01 |
Kit-Misc. Cover for Switches, Relay, Located on Mech. Panel | 792A088G01 |
Latch Check Switch | 662A143H01 |
Latch Checking Switch | 784A907H01# |
Levering-in Assembly Replacement Lit | 8068A62G01 |
Levering-in Screw | 423D184G01 |
Main & Transfer Stack Assembly Kit | 6426C84G02 |
Mech. Assembly W/ Close Spring W/O Spring Charge Motor | 6426C81G01 |
Mech. Small Springs-Kit | 6426C70G01 |
Mechanism-Operated Cell Switch-Installation Kit One (1) Switch (Operates in Connected Position Only) | 693C612G04 |
Mechanism-Operated Cell Switch-Installation Kit One (1) Switch (Operates in Connected/Test Position) | 693C612G01 |
Mechanism-Operated Cell Switch-Installation Kit Three (3) Switch (Operates in Connected Position Only) | 693C612G06 |
Mechanism-Operated Cell Switch-Installation Kit Three (3) Switch (Operates in Connected/Test Position) | 693C612G03 |
Mechanism-Operated Cell Switch-Installation Kit Two (2) Switch (Operates in Connected/Test Position) | 693C612G02 |
Mechanism-Operated Cell Switch-Installation Kit Two(2) Switch (Operates in Connected Position Only) | 693C612G05 |
Mechanism-Operated Cell Switch-Replacement Kit One (1) Switch | 792A147G01 |
Mechanism-Operated Cell Switch-Replacement Kit Two (2) Switches | 792A147G02 |
Misc. Springs Kit | 691C0111G01 |
Misc. Springs Package-Kit | 6426C72G01 |
Motor Cutoff Switch (2 Circuit) 4 Terminals | 8257A30H01 |
Motor Cutoff Switch (4 Circuit) 8 Terminals | 8257A30H02 |
Motor Cutoff Switch and Indicator (Less Switches) | 591C993G07 |
Motors for 125 V DC / 115 V AC breaker built after 1970 | 3755A95G01 |
Motors for 250 V DC / 230 V AC breaker built after 1970 | 3755A95G02 |
Motors for 48 V DC breaker built after 1970 | 3755A95G03 |
Moving Arcing Contact | 691C404G01 |
Moving Contact Operating Rod | 501B713G01 |
Opening (Accelerating) Springs-Kit | 6426C71G01 |
Opening Springs Kit-Cast Solenoid | 691C014G03 |
Opening Springs Kit-Cast Stored Energy | 691C014G01 |
Operating Rod Assembly | 3838A54G01 |
Operations Counter | 592C040H01 |
Pole Unit (For Field Replacement) (Monolithic to PIP)(58KA) | 568F447G03 |
Pole Unit (For Field Replacement) (Monolithic to PIP)(78KA) | 568F447G05 |
Porcelain Hinge Support Assembly | 592C682G01 |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-1200 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-1200 Amp Upper (Short) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-2000 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 15kV-2000 Amp Upper (Short) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-1200 Amp Lower (Long) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-1200 Amp Upper (Short) | N/A |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-2000 Amp Lower (Long) | 437D914G02 |
Porcelain Main Contact Mounting Bottles (Old Design) 5kV-2000 Amp Upper (Short) | 437D914G01 |
Primary Disconnecting Contact | 502A851G01 |
Puffer Tube Assembly | 507B993G01 |
Pull Fuse Holder Assembly w/o Fuses-2 Pole, 30 Amp | 347A062H03 |
Pull Fuse Holder Assembly w/o Fuses-2 Pole, 60 Amp | 783A603H01 |
Rail Latch Assembly | 792A083G01 |
Ratchet & Cam Assembly Less Crank Assembly | 792A120G01 |
Rear Arc Horn Contact | N/A |
Resistor Assembly 115 V AC 60 HZ 250 Ohm | 502A006H13 |
Resistor Assembly 125 V DC 200 Ohm | 73432ECOHE |
Resistor Assembly 230 V AC 60 HZ 750 Ohm | 502A006H15 |
Resistor Assembly 250 V DC 750 Ohm | 73432ECOMB |
Resistor Assembly 48 V DC 25 Ohm | 73432ECOBD |
Resistor for 15 KV / 7500 Ohm | N/A |
Resistor for 15KV / 2000 Ohm | N/A |
Resistor for 5 KV / 2000 Ohm | 74342ECOQO |
Resistor for V5 KV /7500 Ohm | 73432ECOUQ |
Secondary Contact ( Includes Block and Guide Pins | 792A086G01 |
Secondary Contact Handle Assembly | 792A087G01 |
Secondary Contact Receptacle | 4A7850A05 |
Secondary Contact Support | 437D249G01 |
Shunt Strap | 6898D75H01 |
Shunt Trip Magnet (Plus Coil) | 592C921G01 |
Shutter Assembly Complete | 437D937G01 |
Shutter Only | 437D937G02 |
Shutter Roller Kit | 792A084G01 |
Side Sheet-L.H. | 548F260G01 |
Side Sheet-R.H. | 548F259G01 |
Single Pole Unit Assembly Complete (less finger clusters and lift rod) | 568F566G01 |
Small Springs Kit | 691C012G01 |
Small Springs Kit | 691C013G01 |
Space Heater 100W @ 250V | 3614A50H05 |
Space Heater 250W @ 125 V | 3614A50H01 |
Space Heater 250W @ 250 V | 3614A50H02 |
Space Heater 375W @ 125 V | 3614A50H03 |
Space Heater 375W @ 250 V | 3614A50H04 |
Space Heater 95W @ 125 V | 3614A50H04 |
Spring Release Coil 115 V AC 60 HZ | 677C903G05 |
Spring Release Coil 125 V DC | 677C903G02 |
Spring Release Coil 230 V AC 60 HZ | 677C903G06 |
Spring Release Coil 230 V DC | 677C903G03 |
Spring Release Coil 48 V DC | 677C903G01 |
Spring Release Magnet (Plus Coil) | 592C921G01 |
Stationary Arcing Contact | 501B812G01 |
Stud Assemblies-Bottom Stud (4th Position CT) | 792A124G04 |
Stud Assemblies-Bottom Stud (Bus Tie Unit) | 792A124G03 |
Stud Assemblies-Bottom Stud (Feeder) | 792A124G02 |
Stud Assemblies-Top Stud (Bus) | 792A124G01 |
Terminal Block w/ Marking Strip-12 Point | 8261A60G03 |
Terminal Block w/ Marking Strip-8 Point | 8261A60G02 |
Trip Cam Adj. Screw & Nut | 792A118G01 |
Trip Coil 115 V AC 60 HZ for Capacitor Trip Device 382D719G06 | 677C903G03 |
Trip Coil 115 V AC 60 HZ for Capacitor Trip Device 689C166G02 | 677C903G07 |
Trip Coil 125 V DC | 677C903G02 |
Trip Coil 24 V DC | 677C903G04 |
Trip Coil 250 C DC | 677C903G03 |
Trip Coil 48 V DC | 677C903G01 |
Trip Latch & Trigger Kit | 792A245G01 |
Trip Latch & Trigger Kit | 792A247G01 |
Tripping Latch & Trigger Assembly Kit (Link Type) | 792A117G01 |
Tripping Latch & Trigger Assembly Kit (Plunger Type) | 792A117G02 |
Truck-Operated Cell Switch- Three (3) Switch Installation Kit | 792A092G03 |
Truck-Operated Cell Switch- Two (2) Switch Installation Kit | 792A092G02 |
Truck-Operated Cell Switch-One (1) Switch Installation Kit | 792A092G01 |
Truck-Operated Cell Switch-Replacement Kit -One (1) Switch | 792A091G01 |
Tube & Nut Assembly | 8252A34G01 |
Undervoltage Coils 125 VDC | 6911D45G05 |
Undervoltage Coils 250 VDC | 6911D45G01 |
Undervoltage Coils 48 VDC | 6911D45G09 |
Undervoltage Coils Capacitor Time Delay | 677C904G01 |
Undervoltage Trip Device | 693C611G01 |
Wheels-Including Pins and Rings (3 Inch) Set of 4. | 792A085G01 |
Wheels-Including Pins and Rings (4 Inch) Set of 4. | 792A085G02 |
How Can We Help?
Use the form below to check stock on parts, full assemblies, accessories, switchgear or inquire about service work to your circuit breaker. No part number? No problem! Upload a picture or file of your existing equipment. Our expert staff is skilled at identifying replacement parts from customer images.